The "heart" of the grain dryer and its fault phenomena


Release time:

2024-12-25

The grain dryer consists of four parts: heat source, fan, control system, and drying tower. The fan is the heart of the grain dryer. It mainly sends heat to the drying layer for convection heat transfer with the grain, so that the moisture is vaporized and separated from the grain. Therefore, the performance parameters of the fan determine the drying efficiency, energy consumption, and grain drying quality of the dryer. The fan can affect the transmission and distribution energy consumption of the entire drying system and is a very critical part of the grain dryer.

The grain dryer consists of four parts: heat source, fan, control system, and drying tower. The fan is the heart of the grain dryer. It mainly sends heat to the drying layer for convection heat transfer with the grain, so that the moisture is vaporized and separated from the grain. Therefore, the performance parameters of the fan determine the drying efficiency, energy consumption, and grain drying quality of the dryer. The fan can affect the transmission and distribution energy consumption of the entire drying system and is a very critical part of the grain dryer.

It is worth noting that according to the fan testing of the National Equipment Quality Supervision and Inspection Center for many years, many fans have problems under rated conditions. Therefore, when the grain dryer is drying, it often encounters faults such as fan high temperature tripping. In order to solve the losses caused by fan failure in the normal state of the grain dryer, we will summarize the following experience for you.

1. When the grain dryer equipment system enters the working state, the fan should be turned on and run in sequence. At the beginning of the work, the vibration of the bearing part is very small, but as the running time increases, the dust in the fan will be unevenly attached to the impeller, gradually destroying the dynamic balance of the fan, and gradually increasing the vibration of the bearing. Once the vibration reaches the allowable value of the fan 11mm/s, the fan is shut down for repair (remove dust accumulation and redo dynamic balance). Because it is very dangerous at this time, users must not force it.

2. The normal bearing temperature of the fan is ≤70℃. If it rises to 70℃, the electrical control cabinet should alarm. At this time, the cause should be found. First, check whether the cooling water is normal? Is the bearing oil level normal?

3. During the start-up, shutdown or operation of the fan, if any abnormal phenomenon (such as abnormal sound, abnormal vibration, abnormal temperature rise) is found, it should be checked immediately. The cause of the small fault found during the inspection should be promptly identified and eliminated. If a major fault is found (such as severe vibration, impact of the fan, and a sharp rise in bearing temperature, etc.), it should be stopped immediately for inspection.

4. Master the correct way to open the fan damper. Failures caused by careless operation of the damper are common.